Solicitation Number: 70Z085Q250011548
Date Added: March 07, 2025
THIS IS TO BE AWARDED OFF OF LOWEST PRICE TECHNICALLY ACCEPTABLE AND PAST PREFORMANCE.
STATEMENT OF WORK (SOW)
FOR
USCGC WEDGE Renew Piping Insulation, Overhead Insulation and Conduct Overhead Repairs
WEDGE has an immediate need for technical support for tasks outlined in this Statement of Work (SOW).
1.0 GENERAL
The 75’ WLR asset, USCGC WEDGE needs approximately 500 linear feet of pipe insulation, 1500 square feet of overhead insulation, and 300 sq ft of overhead panels.
The scope of this contract is defined by the efforts and tools required to support USCGC WEDGE (WLR 75307). The Contractor shall provide all labor, materials, and tools necessary to install insulation and bulkhead panels.
Table 1 -Pipe Insulation Renewal
Description
(System/ Pipe Diameter/ Linear Feet)
Location
Drawing
Tender Chill Water/ Potable Water Piping / .5 in / 50 ft
Galley/Mess deck/Crew Berthing/ Crew Head/Laundry/XPO State Room/ OIC State Room
See below
Tender Chill Water/ Potable Water Piping / .75 in / 50 ft
Galley/Mess deck/Crew Berthing/ Crew Head/Laundry/XPO State Room/ OIC State Room
See below
Tender Chill Water/ Potable Water Piping / .875 in / 50 ft
Galley/Mess deck/Crew Berthing/ Crew Head/Laundry/XPO State Room/ OIC State Room
See below
Tender Chill Water/ Potable Water Piping / 1 in / 100 ft
Galley/Mess deck/Crew Berthing/ Crew Head/Laundry/XPO State Room/ OIC State Room
See below
Tender Chill Water/ Potable Water Piping / 1 .25 in / 125 ft
Galley/Mess deck/Crew Berthing/ Crew Head/Laundry/XPO State Room/ OIC State Room
See below
Tender Waste Water Piping / 1.5 in / 50 ft
Galley/Mess deck/Crew Berthing/ Crew Head/Laundry/XPO State Room/ OIC State Room
See below
Tender Waste Water Piping / 1.75 in / 25 ft
Galley/Mess deck/Crew Berthing/ Crew
See below
Tender Waste Water Piping / 2.0 in / 50 ft
Galley/Mess deck/Crew Berthing/ Crew Head/Laundry/XPO State Room/ OIC State Room
See below
Table 2 – Overhead Insulation Renewal
Description
(Area/Approximate Square feet)
Location
Insulation Material
Overheads/1500 sq feet
Galley/Mess deck/Crew Berthing/ Crew Head/Laundry/XPO State Room/ OIC State Room
BFG 261 (MIL-C-20079) or equivalent
Table 3 – Overhead Repairs
Description
(Area/Approximate Size)
Location
Drawing
300 sq ft of overhead panels
Galley/Mess Deck
See below
The goal is to return CGC WEDGE habitability areas to an appropriately insulated area.
The following documents provide specifications, standards, or guidelines that must be complied with in order to meet the requirements of this contract:
Surface Forces Logistics Center Standard Specification (SFLC Std Spec) 0000, 2022, General Requirements
Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures
ASTM International (ASTM) F683, 2003, Standard Practice for Selection and Application of Thermal Insulation for Piping and Machinery
NAVSEA Drawing 804-5959214, Rev-, Piping Insulation - Installation Details
Coast Guard Drawing 75D-WAGL-3801-1 Vent Heating & A/C
Coast Guard Drawing 75D-WAGL-3901-1, Insulation & Sheathing Schedule (75306-75307)
Coast Guard Drawing 75D-WAGL 3902-1 Rev 1, JOINER DETS ENG RM (75306-75307
Coast Guard Drawing 75D-WAGL 3902-2 Rev 2, JOINER DETS MN DK & UPPER DK (75306-75307)
Coast Guard Drawing 75D-WAGL 3902-3 Rev 2, JOINER DETS WHEELHOUSE (75306-75307)
Unless otherwise stated, this contract applies to on-site support for USCGC WEDGE (WLR 75307) in Mobile, AL.
2.1 RENEW CHILLWATE
Set-Aside: Total Small Business Set-Aside (FAR 19.5) (SBA)
Place of Performance: Mobile, Alabama, UNITED STATES
NAICS Codes:
336611
Files:
SAM.gov
Sep 14, 2026 Active