Solicitation Number: 36C25025R0046
Date Added: January 28, 2025
STATEMENT OF WORK FY25 Joint Commission Statement of Conditions and Fire/Life Safety Code Review. Revised 1/27/2025 1. Contracting Officer s Representative (COR) Name: Conner Appelgate Section: Engineering Address: 3200 Vine St. Cincinnati, Oh 45220 2. Background & Scope Provide labor, materials, and equipment to prepare the 2025 Joint Commission Statement of Building Conditions for Buildings #1, 2, 3, 8, 14, 15, 16, & 64 at our Cincinnati Campus. The requirements for buildings 1 and 2 at the main campus shall be completed first and foremost as these are directly tied to Joint Commission requirements. This includes: Conducting a survey to determine compliance with current editions of NFPA 101, Life Safety Code. Evaluate the existing fire and smoke barrier walls and make recommendations to decommission the walls and cross corridor doors that are no longer required. Conduct a random survey of 25% of the fire and smoke barrier walls, above the ceilings, to confirm locations and construction. All life safety elements represented by NFPA 101 must be labeled such as different fire and smoke barrier times (30 min., 1 hour, 2 hours etc.), suite designations, areas open to corridor-with smoke detection, Areas open to corridor with no smoke detection required and proper distinction between them. All life safety, fire safety elements are labeled in the drawings as well as given a numerical value, with applicable updates made for altered components. (Egress pathways, exit signage, sprinkler systems, suppression systems, hazardous area protections, equipment and utility shut-offs). A numbering system shall be developed and illustrated on the statement of condition drawings so that maintenance may utilize these as a primary reference for future joint commission documentation. Ref A_2020 Fire Barrier Inspection (Reference for Numbering) and Ref B_2020 Fire Door Inspection (Reference for Numbering) demonstrate what the numeric numbering format should entail, Ref C_2020 SOC Set (Reference for Numbering) demonstrates what a statement of conditions set with the reference numbers incorporated might look like, and Ref D_2022 SOC Set (Most Recent Reference) is the most recent statement of conditions set for buildings 1 and 2 of the main campus. Deviations from NFPA 101 will be identified and documented, so that maintenance related work orders and Plans for Improvement (PFI) can be developed. Review our electronic Joint Commission data and assist in its update. Provide a Statement of Qualifications, General Building Occupancy, Equivalencies approved by the Joint Commission, Life Safety Assessments, Floor Plans showing features of fire protection & life safety, recommendations on how to correct any non-compliant items, and a preliminary Plan for Improvement on items that are not easily correctable. All these documents shall be in Microsoft Word format. Any deficiencies that can be corrected through a normal work order process will be provided in a separate list. A final paper and electronic copy of the Statement of Conditions, after all the reviews have been completed. The C&A requirements do not apply, and that a Security Accreditation Package is not required. Address and incorporate VAMC feedback into final deliverable. Upon completion of the update to the drawing set, a licensed Professional Engineer (P.E.) will perform a final review and certification of the plan. 3. Security Requirements Contractors shall have Flash Badge (PIV) present while on site. If a flash badge is not present, contractors must visit VA Police Service to obtain a temporary badge by exchanging their driver s license. 4. Place of Performance This product will be used at two locations of the Cincinnati VAMC, the main campus (3200 Vine St. Cincinnati, OH 45220) and at the Fort Thomas Domiciliary (1000 S Fort Thomas Ave, Fort Thomas, KY 41075). The majority of the work will occur at the main campus. 5. Period of Performance The period of performance for this contract is 30 calendar days. 6. Record Management a. Contractor shall comply with all applicable records management laws and regulations, as well as National Archives and Records Administration (NARA) records policies, including but not limited to the Federal Records Act (44 U.S.C. chs. 21, 29, 31, 33), NARA regulations at 36 CFR Chapter XII Subchapter B, and those policies associated with the safeguarding of records covered by the Privacy Act of 1974 (5 U.S.C. 552a). These policies include the preservation of all records, regardless of form or characteristics, mode of transmission, or state of completion. b. In accordance with 36 CFR 1222.32, all data created for Government use and delivered to, or falling under the legal control of, the Government are Federal records subject to the provisions of 44 U.S.C. chapters 21, 29, 31, and 33, the Freedom of Information Act (FOIA) (5 U.S.C. 552), as amended, and the Privacy Act of 1974 (5 U.S.C. 552a), as amended and must be
Set-Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC)
Place of Performance: Cincinnati, Ohio, UNITED STATES
NAICS Codes:
541310
Files:
SAM.gov
Oct 31, 2026 Active
SAM.gov
No deadline yet